Beam Sizes (Based on No. 2 or better Ponderosa Pine and Southern Pine Treated for weather and/or ground exposure)
X = Joist Length
| X |
Species |
|
|
|
|
Post Spacing |
|
|
|
|
|
|
| |
|
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
| 6 |
Southern Pine |
1-2x6 |
1-2x6 |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x10 |
| |
Ponderosa Pine |
1-2x6 |
1-2x6 |
2-2x8 |
2-2x8 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
| 7 |
Southern Pine |
1-2x6 |
1-2x6 |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x10 |
2-2x12 |
| |
Ponderosa Pine |
1-2x6 |
1-2x6 |
1-2x8 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x10 |
| 8 |
Southern Pine |
1-2x6 |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
2-2x12 |
| |
Ponderosa Pine |
1-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x10 |
3-2x10 |
3-2x10 |
3-2x12 |
| 9 |
Southern Pine |
1-2x6 |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
| |
Ponderosa Pine |
1-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x10 |
3-2x10 |
3-2x10 |
3-2x12 |
3-2x12 |
| 10 |
Southern Pine |
1-2x6 |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
3-2x10 |
| |
Ponderosa Pine |
1-2x6 |
1-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
| 11 |
Southern Pine |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
3-2x12 |
| |
Ponderosa Pine |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
| 12 |
Southern Pine |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x10 |
3-2x12 |
| |
Ponderosa Pine |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x12 |
3-2x12 |
Eng Bm |
Eng Bm |
| 13 |
Southern Pine |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
| |
Ponderosa Pine |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x10 |
2-2x12 |
2-2x12 |
2-2x12 |
3-2x12 |
3-2x12 |
Eng Bm |
Eng Bm |
| 14 |
Southern Pine |
1-2x6 |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x10 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
3-2x12 |
| |
Ponderosa Pine |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
Eng Bm |
Eng Bm |
| 15 |
Southern Pine |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
| |
Ponderosa Pine |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
3-2x10 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
Eng Bm |
Eng Bm |
| 16 |
Southern Pine |
2-2x6 |
2-2x6 |
2-2x8 |
2-2x8 |
2-2x10 |
2-2x12 |
2-2x12 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
| |
Ponderosa Pine |
2-2x6 |
2-2x8 |
2-2x10 |
2-2x10 |
3-2x10 |
3-2x10 |
3-2x12 |
3-2x12 |
Eng Bm |
Eng Bm |
Eng Bm |
Joist sections cantilevered over beams must be calculated as (2x length) for beam sizing. |